products

VEHICULAR MULTIPLEXED/DIGITAL SYSTEMS

Image
ITALWATT is also able to design an entire vehicle system, starting from customer’s technical speci cation using the most advanced simulation tools and Model-Based Design approach to achieve the highest performance level.
*All images are for illustrative purposes.
Starting from the simplest with only one Body Computer equipped with I/O up to the most complex where a central Body Computer sends and receives a series of information through CANBus lines to remote control units for the management and diagnostics of all vehicle services.
examples
4x4 example

RUFR

5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)

RUFR

5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)

DC30

1 DC Converter 30A (DC30)

CT

1 Car Talker System (CT)

CT

1 Car Talker System (CT)

CT

1 Car Talker System (CT)

RUC

5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)

BC

1 Body Computer (BC)

EDR

1 Event Data / Tachograph Recorder (EDR)

CP

1 Control Panel (CP)

PDB

1 Power Distribution Box (PDB)

AHM

2 Altitude Heater Module (AHM)

RURL

5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)

RURR

5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)

AHM

2 Altitude Heater Module (AHM)

DC60

1 DC Converter 60A (DC60)
  • RUFR

    5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
  • RUFR

    5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
  • DC30

    1 DC Converter 30A (DC30)
  • CT

    1 Car Talker System (CT)
  • CT

    1 Car Talker System (CT)
  • CT

    1 Car Talker System (CT)
  • RUC

    5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
  • BC

    1 Body Computer (BC)
  • EDR

    1 Event Data / Tachograph Recorder (EDR)
  • CP

    1 Control Panel (CP)
  • PDB

    1 Power Distribution Box (PDB)
  • AHM

    2 Altitude Heater Module (AHM)
  • RURL

    5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
  • RURR

    5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
  • AHM

    2 Altitude Heater Module (AHM)
  • DC60

    1 DC Converter 60A (DC60)
    • 1 Body Computer (BC)
    • 5 Input/output Units (RUC, RUFL, RUFR, RURR, RURL)
    • 1 Event Data / Tachograph Recorder (EDR)
    • 1 Car Talker System (CT)
    • 1 Power Distribution Box (PDB)
    • 1 Control Panel (CP)
    • 2 Altitude Heater Module (AHM)
    • 1 DC Converter 30A (DC30)
    • 1 DC Converter 60A (DC60)
    6x6 example

    RUFL

    4 Input/output Units (RU)

    RUFR

    4 Input/output Units (RU)

    SCEM

    1 EDC Filtering Box (SCEM)

    BC

    1 Body Computer (BC)

    CP4

    3 LCD Control Panel (CP10 – CP6 – CP4)

    CP6

    3 LCD Control Panel (CP10 – CP6 – CP4)

    CP10

    3 LCD Control Panel (CP10 – CP6 – CP4)

    RUC

    4 Input/output Units (RU)

    HVAC

    1 Heating Ventilation Air Conditioning (HVAC)

    RUR

    4 Input/output Units (RU)

    REC

    1 Ramp Controller (REC)
    • RUFL

      4 Input/output Units (RU)
    • RUFR

      4 Input/output Units (RU)
    • SCEM

      1 EDC Filtering Box (SCEM)
    • BC

      1 Body Computer (BC)
    • CP4

      3 LCD Control Panel (CP10 – CP6 – CP4)
    • CP6

      3 LCD Control Panel (CP10 – CP6 – CP4)
    • CP10

      3 LCD Control Panel (CP10 – CP6 – CP4)
    • RUC

      4 Input/output Units (RU)
    • HVAC

      1 Heating Ventilation Air Conditioning (HVAC)
    • RUR

      4 Input/output Units (RU)
    • REC

      1 Ramp Controller (REC)
      • 1 Body Computer (BC)
      • 4 Input/output Units (RU)
      • 3 LCD Control Panel (CP10 – CP6 – CP4)
      • 1 Ramp Controller (REC)
      • 1 Heating Ventilation Air Conditioning (HVAC) 1 EDC Filtering Box (SCEM)
      ideas first

      Have an idea?
      We can do it!

      ALL FOR YOUR BUSINESS